GEAR MOTOR MR 752 52
TYPE | RATIO | L mm |
*R.P.M. no load min-1 |
*R.P.M. S 1 min-1 |
S1 Torque Nm |
*R.P.M. S2 min-1 |
S2 Torque Nm |
Max Torque Nm |
I max 24 Vdc |
MR 752 52 1/4 | 4 | 137 | 660 | 550 | 0,29 | 430 | 0,72 | 2 | 7 |
MR 752 52 1/6 | 6 | 144 | 440 | 380 | 0,43 | 280 | 1,1 | 3 | 7 |
MR 752 52 1/16 | 16 | 152 | 165 | 140 | 1,03 | 105 | 2,6 | 7,2 | 7 |
MR 752 52 1/24 | 24 | 152 | 105 | 90 | 1,54 | 70 | 3,9 | 10,8 | 7 |
MR 752 52 1/36 | 36 | 159 | 70 | 60 | 2,3 | 47 | 5,8 | 16,2 | 7 |
MR 752 52 1/64 | 64 | 169 | 40 | 33 | 3,5 | 26 | 8,7 | 24,3 | 7 |
MR 752 52 1/96 | 96 | 176 | 32 | 26 | 6 | 19 | 13,2 | 32 | 7 |
MR 752 52 1/144 | 144 | 169 | 21 | 18 | 8 | 14 | 19,5 | 45 | 5,5 |
MR 752 52 1/216 | 216 | 176 | 14 | 11 | 13,5 | 10 | 20/2A | 45 | 3,2 |
MR 752 52 1/384 | 384 | 192 | 8 | 6,5 | 15 | 5 | 30 | 45 | 5,5 |
MR 752 52 1/576 | 576 | 192 | 5,5 | 4,8 | 16,5/0,95 A | 4 | 31/1,6 A | 45 | 3,8 |
MR 752 52 1/864 | 864 | 192 | 3,7 | 3,1 | 18/0,75 A |
2,8 | 32/1 A | 45 | 2,5 |
Length "L" of the gearmotor as a funtion of reduction and output number of revolution with the standard motor
752 40 output W 3200 Rpm loadness, 12 or 24 Vdc. Starting corrent 7 A. (14A x 12Vdc)
752 40 output W 3200 Rpm loadness, 12 or 24 Vdc. Starting corrent 7 A. (14A x 12Vdc)
Output shaft is supported by two coupled screened bearings.
The motor has an electrical suppressor system for the CE standard.
The motor’s surface and reducer’s surface are both plated to avoid corrosion.
Connecting wires 0,75 x 250 mm.
The motor has an electrical suppressor system for the CE standard.
The motor’s surface and reducer’s surface are both plated to avoid corrosion.
Connecting wires 0,75 x 250 mm.
*The speed rotation can change of ±10%.
The S1 load test was made using a (1,5A) corrent in the air with an increase of temperature of 70° C.
The S2 test was made using a (2,8 A) corrent in the air with a 50% timing 5' with an increase of temperature
of 80° C max. The starting corrent is (I max) and must not mantained for more than 2".
The S2 test was made using a (2,8 A) corrent in the air with a 50% timing 5' with an increase of temperature
of 80° C max. The starting corrent is (I max) and must not mantained for more than 2".
Max load on the output shaft: Axial 200 N, Radial 300 N
It is possible to apply an encoder.